We are here to assist you.
Health Advisor
+91-8877772277Available 7 days a week
10:00 AM – 6:00 PM to support you with urgent concerns and guide you toward the right care.
* Prices shown are indicative. Clicking "Buy" will take you to the retailer's website. Doctar may earn a small affiliate commission at no extra cost to you.
This product is an absorbable, undyed, monofilament surgical suture made from Poliglecaprone 25. It is designed for use in soft tissue approximation and ligation, providing a reliable method for closing wounds and securing tissues. The suture is engineered to offer a balance of tensile strength and pliability, facilitating ease of handling during surgical procedures.
Its absorbable nature means it is gradually broken down by the body over time, eliminating the need for subsequent removal, which can reduce patient discomfort and the risk of complications associated with retained foreign material. The monofilament construction minimizes drag through tissue, contributing to reduced tissue trauma during insertion and knot tying. The suture is presented with a pre-attached needle, specifically a 13 mm, 3/8 circle reverse cutting needle with a Prime point.
This needle configuration is selected for its sharpness and ability to penetrate various tissue types with precision, particularly in procedures where accurate placement is critical.
The mechanism of action for this suture relies on its material composition and physical structure. Poliglecaprone 25 is a synthetic polymer that undergoes hydrolysis within the body. This process breaks down the suture into smaller, soluble components that are then metabolized and eliminated.
The rate of absorption is predictable, typically occurring over a period of several weeks, providing sufficient wound support during the critical healing phases. The undyed nature of the suture aids in visualization within the surgical field without obscuring tissue detail. The Prime Reverse Cutting needle is designed with a triangular point that is reversed relative to the needle's curvature, which helps to reduce the cutting force required to penetrate tissue and minimizes the risk of tearing delicate structures.
The MultiPass designation indicates a coating applied to the suture, which is intended to enhance its lubricity, allowing for smoother passage through tissues and potentially reducing friction-induced trauma.
Key features and benefits of this surgical suture include its absorbable nature, which negates the need for suture removal, thereby simplifying post-operative care and potentially improving patient outcomes. The monofilament design contributes to reduced tissue drag and minimal tissue reaction, promoting a more favorable healing environment. The high tensile strength of the suture provides secure wound closure, essential for maintaining tissue apposition during healing.
The accompanying 13 mm, 3/8 circle Prime Reverse Cutting needle is engineered for precision and sharpness, facilitating accurate placement in a variety of surgical contexts. The MultiPass coating further enhances handling characteristics, making the suture easier to manipulate for the surgeon. These attributes collectively support effective wound management and patient comfort.
This suture is intended for use by qualified medical professionals, including surgeons, physicians, and other healthcare providers trained in surgical techniques and wound closure. It is suitable for a range of applications involving soft tissue approximation and ligation in various surgical specialties. Typical applications include procedures in general surgery, plastic surgery, dermatology, and other fields where absorbable sutures are indicated for subcutaneous closure, skin closure (where appropriate for absorbable sutures), and internal tissue approximation.
It is particularly useful in procedures where the removal of non-absorbable sutures would be challenging or undesirable. Caregivers may also be involved in post-operative wound care instructions related to the suture's presence and eventual absorption.
Important usage notes include verifying the integrity of the packaging before use; any damage to the foil pouch may compromise sterility. This product is intended for single use only and must not be resterilized or reused, as this could lead to contamination or loss of material integrity. The suture and needle should be handled with appropriate aseptic techniques to prevent infection.
Storage recommendations typically involve keeping the product in a cool, dry place, away from direct sunlight and extreme temperatures, to maintain its physical and chemical properties. It is crucial to follow institutional protocols for suture handling and disposal. The suture is designed for specific tissue types and procedures; therefore, its selection should be based on the surgeon's judgment and the specific requirements of the patient and the surgical intervention.
This product is an absorbable, undyed, monofilament surgical suture made from Poliglecaprone 25, USP 5-0, with a 13 mm, 3/8 circle Prime Reverse Cutting needle. It is used for soft tissue approximation and ligation.
Ethicon Johnson
Ethicon Johnson - NW2826 - Vicryl Sutures USP 1, 1/2 Circle Reverse Cutting Heavy Portt - NW2826 - 12 Foils Box
Ethicon Johnson
Ethicon Johnson - NW9254 - PDS II Sutures USP 0, 1/2 Circle Round Body Heavy NW9254 - 12 Foils Box
Ethicon Johnson
Ethicon Johnson - NW882 - Ethibond Excel Sutures USP 4-0, W882 -12 Foils Box
Ethicon Johnson
Ethibond Sutures USP 4-0, 1/4 Circle Spatulated Ethalloy Double Needle -12 Foils
Ethicon Johnson
Ethibond Sutures USP 5-0, 1/4 Circle Spatulated Ethalloy Double Needle -12 Foils
Ethicon Johnson
Ethicon Johnson - NW682 - Ethibond Sutures USP 4-0, 1/4 Circle Spatulated Micro Point - NW682 -12 Foils
Ethicon Johnson
Ethicon Johnson - NW687 - Ethibond Sutures USP 2-0, 1/2 Circle Tapercut Double Needle - NW687 - 12 foils
Ethicon Johnson
Ethicon Johnson - W6987 - Ethibond Sutures USP 2-0, 1/2 Circle Tapercut 2 - W6987 - 12 Foils Box